OPERATION CHECK
1. CHECK BASIC FUNCTIONS
(a) When the back door is partially closed, check that the motor operates to fully close (lock) the back door.
(b) Check that the back door can be opened.
(c) When the back door is partially closed and then the motor starts normal operation, push the back door opener switch assembly and pull up the back door to open it. At this time, check that the motor starts the reverse operation and then stops.
(d) Immediately after the back door is partially closed (the motor has not started operation yet), push the back door opener switch assembly to open the back door. Check that the motor does not operate at this time.
How To Proceed With Troubleshooting
InitializationStartability Malfunction (P1604)
DESCRIPTION
This DTC is stored when the engine does not start even though the STA signal
is input or when the engine takes a long time to start, and when the engine speed
is low or the engine stalls just after the engine starts.
Using the Techstream, the ...
Initialization
INITIALIZATION
1. RESET BACK DOOR CLOSE POSITION
NOTICE:
Perform initialization of the power back door system (power back door ECU initialization)
if one of the following is performed:
The cable is disconnected from the negative (-) battery termin ...
Removal
REMOVAL
PROCEDURE
1. REMOVE YAW RATE AND ACCELERATION SENSOR
HINT:
Refer to the instructions for Removal of the yaw rate and acceleration sensor
(See page ).
2. REMOVE REAR NO. 2 AIR DUCT
3. REMOVE REAR NO. 1 AIR DUCT
4. REMOVE FRONT NO. 2 FLOO ...