Toyota Venza manuals

Toyota Venza: Initialization

INITIALIZATION

1. INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR ASSEMBLY (ALL DOORS))

CAUTION:

When the power window regulator motor assembly is reinstalled or replaced, the power window control system must be initialized. Functions such as the auto up/down, jam protection, remote control and key-off operation do not operate if the initialization is not performed.

HINT:

When the battery is replaced, it is not necessary to initialize the power window regulator motor assembly.

NOTICE:

  • When the power window regulator motor assembly is replaced, DTC B2313 is output. Clear the DTC after the initialization.
  • When performing initialization, do not perform any other procedures.
  • After a door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the auto up function is used, due to detection of a value different from the operation learned value of the door glass movement speed. In such cases, the auto up function can be reinitialized by repeating the following operation at least 5 times:
    1. Open the power window by fully pushing down the power window regulator master switch assembly or power window regulator switch assembly.
    2. Close the power window by fully pulling up the power window regulator master switch assembly or power window regulator switch assembly and holding it at the auto up position.
  • If the initialization is not completed properly, the LIN communication system may have a malfunction (See page ).

(a) Initialization procedure when replacing the power window regulator motor assembly with a new one:

(1) Connect the battery and turn the ignition switch to ON.

(2) Fully open the window by fully pushing down the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.

(3) Fully close the power window by fully pulling up the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.

(b) Initialization procedure when removing/installing the power window regulator motor assembly:

(1) Connect the battery and turn the ignition switch to ON.

(2) Fully close the power window by fully pulling up the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled, release the switch and fully pull it again).

(3) Fully open the window by pushing down the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.

(4) Release the power window regulator master switch assembly or power window regulator switch assembly. Then fully push down and hold the switch for 4 seconds or more.

(5) Fully close the power window by fully pulling up the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete the initialization.

(c) Initialization procedure when the power window does not fully open:

(1) Connect the battery and turn the ignition switch to ON.

(2) Fully close the power window by fully pulling up the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled, release the switch and fully pull it again).

(3) Fully open the window by pushing down the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.

(4) Release the power window regulator master switch assembly or power window regulator switch assembly. Then fully push down and hold the switch for 4 seconds or more.

(5) Fully close the power window by fully pulling up the power window regulator master switch assembly or power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete the initialization.

Customize Parameters
CUSTOMIZE PARAMETERS 1. CUSTOMIZING FUNCTION WITH TECHSTREAM (REFERENCE) HINT: The following items can be customized. NOTICE: When the customer requests a change in a function, first make ...

Problem Symptoms Table
PROBLEM SYMPTOMS TABLE HINT: Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are lis ...

Other materials about Toyota Venza:

Operation Check
OPERATION CHECK 1. CHECK AUTO OPERATION NOTICE: Make sure that initialization is completed before inspection (See page ). HINT: When pressing the switch for 0.3 seconds or less, the roof glass moves but auto operation does not operate. (a) Turn the i ...

Terminals Of Ecu
TERMINALS OF ECU NOTICE: Turn the ignition switch off before measuring the resistances between CAN bus main wires and between CAN bus branch wires. Turn the ignition switch off before inspecting CAN bus wires for a ground short. After ...

Back Door cannot be Opened
DESCRIPTION When the back door cannot be opened, one of the following may be malfunctioning: 1) power back door ECU (power back door motor unit)*1 or back door closer ECU (multiplex network door ECU)*2, 2) back door lock assembly, 3) back door opener swit ...