DTC CHECK / CLEAR
1. CHECK DTC
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Read the DTCs by following the directions on the Techstream screen.
HINT:
Refer to the Techstream operator's manual for further details.
2. CLEAR DTC
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Clear the DTCs by following the directions on the Techstream screen.
HINT:
Refer to the Techstream operator's manual for further details.
Terminals Of Ecu
Data List / Active TestInitialization
INITIALIZATION
1. RESET TRANSAXLE COMPENSATION CODE
NOTICE:
If the following parts have been replaced, initialize the TCM and perform
the following "Reset Memory" and "Perform Road Test to Allow TCM to learn"
steps.
- ...
Fail-safe Chart
FAIL-SAFE CHART
1. Fail-safe
This function minimizes the loss of operation when any abnormality occurs in
a sensor or solenoid.
Fail-safe Control List
Malfunction Part
Function
Input Turbine Speed Sensor
...
Input / Turbine Speed Sensor Circuit Malfunction (P0715,P0717)
DESCRIPTION
This sensor detects the rotation speed of the turbine which shows the input revolution
(speed) of the transaxle. By comparing the input turbine speed signal (NT) with
the counter gear speed sensor signal (NC), the TCM detects the shift timing ...